double fault to earth

double fault to earth
  1. двойное замыкание на землю

 

двойное замыкание на землю
Совокупность двух однофазных замыканий на землю в различных, но электрически связанных частях электроустановки
[ГОСТ 26522-85]

0542

Рис. ABB
Двойное замыкание на землю в сети, изолированной от земли
(Double fault in a network insulated from earth)

Параллельные тексты EN-RU

 

The possibility of a double fault to earth (the first fault on the supply side of the poles of one polarity an the second one on the load side of the poles of the other polarity) is not considered, therefore it is suggested the use of a device to monitor the insulation to earth, capable of signaling the decrease of the insulation to earth as a consequence of a first fault to earth
[ABB]

Возможность двойного замыкания на землю (первое – замыкание одного из полюсов сети со стороны источника питания, второе – замыкание другого полюса со стороны нагрузки) не рассматривается. Однако предлагается использовать устройство контроля изоляции сети относительно земли. Это устройство должно сигнализировать об ухудшении изоляции сети электроустановки относительно земли при первом замыкании на землю.
[Перевод Интент]

Тематики

  • электробезопасность
  • электроснабжение в целом
  • электроустановки

Классификация

>>>

EN

  • double fault to earth


Англо-русский словарь нормативно-технической терминологии. . 2015.

Игры ⚽ Нужно сделать НИР?

Полезное


Смотреть что такое "double fault to earth" в других словарях:

  • fault — fault1 W3S2 [fo:lt US fo:lt] n ▬▬▬▬▬▬▬ 1¦(responsible for mistake)¦ 2 at fault 3¦(something wrong with something)¦ 4¦(somebody s character)¦ 5 through no fault of her/my etc own 6¦(crack)¦ 7 generous/loyal/honest etc to a fault 8¦(tennis)¦… …   Dictionary of contemporary English

  • Earth Sciences — ▪ 2009 Introduction Geology and Geochemistry       The theme of the 33rd International Geological Congress, which was held in Norway in August 2008, was “Earth System Science: Foundation for Sustainable Development.” It was attended by nearly… …   Universalium

  • earth — /errth/, n. 1. (often cap.) the planet third in order from the sun, having an equatorial diameter of 7926 mi. (12,755 km) and a polar diameter of 7900 mi. (12,714 km), a mean distance from the sun of 92.9 million mi. (149.6 million km), and a… …   Universalium

  • Double switching — A single switched relay can close inadvertently in response to a single false feed current. A double switched relay cannot close inadvertently with the application of the same current. At least two separate faults would be required to allow this… …   Wikipedia

  • Earth's magnetic field — Computer simulation of the Earth s field in a normal period between reversals.[1] The tubes represent magnetic field lines, blue when the field points towards the center and yellow when away. The rotation axis of the Earth is centered and… …   Wikipedia

  • Hayward Fault Zone — The Hayward Fault Zone is a geologic fault zone capable of generating significantly destructive earthquakes. About 60 kilometers long, it lies mainly along the western base of the hills on the east side of San Francisco Bay. It runs through… …   Wikipedia

  • General Protection Fault (webcomic) — Infobox comic strip title= General Protection Fault caption= author= Jeffrey T. Darlington url= http://www.gpf comics.com/ rss= http://www.gpf comics.com/gpf.rss atom= status= Monday, Wednesday, Friday first= 1998 11 02 [http://www.gpf… …   Wikipedia

  • Chris Benoit double murder and suicide — Chris Benoit double murder suicide Location Fayetteville, Georgia, United States Date June 22, 2007 – June 25 …   Wikipedia

  • двойное замыкание на землю — Совокупность двух однофазных замыканий на землю в различных, но электрически связанных частях электроустановки [ГОСТ 26522 85] Рис. ABB Двойное замыкание на землю в сети, изолированной от земли (Double fault in a network insulated from earth)… …   Справочник технического переводчика

  • Snoopy — Peanuts character Snoopy as The Ace of World War I fighter pilot First appearance October 4, 1950 (comic strip) A Charlie Brown Christmas (television special) …   Wikipedia

  • ГОСТ Р МЭК 60050-826-2009: Установки электрические. Термины и определения — Терминология ГОСТ Р МЭК 60050 826 2009: Установки электрические. Термины и определения оригинал документа: ( длительный ) допустимый ток ((continuous) current carrying capacity ampacity (US)): Максимальное значение электрического тока, который… …   Словарь-справочник терминов нормативно-технической документации


Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»